为什么vtp 模式改不了

w1(vlan)#vtp s
Setting device to VTP SERVER mode.
% not enough space on flash to store vlan database. trying squeeze...First create squeeze log by erasing the entire device

% error squeezing flash - (Missing or corrupted log)
% not enough space on flash to store vlan database. trying squeeze...First create squeeze log by erasing the entire device

% error squeezing flash - (Missing or corrupted log)
sw1(vlan)#exit
In CLIENT state, no apply attempted.
Exiting....
sw1#show vtp s
VTP Version : 2
Configuration Revision : 0
Maximum VLANs supported locally : 256
Number of existing VLANs : 6
VTP Operating Mode : Client
VTP Domain Name : 123
VTP Pruning Mode : Disabled
VTP V2 Mode : Disabled
VTP Traps Generation : Disabled
MD5 digest : 0xB3 0x32 0xDC 0x98 0x59 0x49 0xB9 0x35
Configuration last modified by 0.0.0.0 at 3-1-02 00:03:12

你这个是不是虚拟机?是虚拟机话确实会有这种情况not enough space on flash to store vlan database,就是说你的flash的内存不够。那是你的虚拟机设置时给的内存太少了。可以更改的。
假如不是虚拟机,那应该是你的flash里放了太多的配置文件,将那些配置文件删除一些释放一些空间就好了
温馨提示:答案为网友推荐,仅供参考

相关了解……